July 2, 2026 | Arlington, TX
Customer called because they suspected a bad capacitor. We inspected the system, confirmed the capacitor had failed, and replaced it. After testing the unit, we verified everything is running properly and cooling as it should.
July 1, 2026 | Fort Worth, TX
Customer called because their home was not cooling properly. We found a refrigerant leak at the indoor coil and recharged the system with refrigerant. After completing the service, we verified the system was operating properly and cooling again.
July 1, 2026 | Arlington, TX
Customer scheduled a two-system A/C maintenance. During the inspection, we found one condenser needed a new fan motor, so we replaced the fan motor and installed a new capacitor. We also replaced the air filters, tested both systems, and confirmed everything is running properly and cooling as it should.
June 30, 2026 | Cleburne, TX
Customer called because their home was not cooling properly. We found the indoor fan was not running due to the blower motor overheating, which was caused by a dirty air filter restricting airflow. We replaced the filter, verified the blower motor was operating properly, and confirmed the system is now ...
June 29, 2026 | Springtown, TX
We installed a 3-ton heat pump, but at the time of installation there was no incoming power, so we had to return once power was available. During the startup, we found a faulty TXV at the air handler, replaced it, recharged the system with refrigerant, and verified everything is now ...
June 28, 2026 | Burleson, TX
Customer called because the home was not maintaining the set temperature. We found the indoor coil frozen upon arrival and the outdoor condenser dirty. We cleaned the condenser, checked the amp draw on the compressor, fan motor, and blower motor, and confirmed the system is now operating properly.
June 26, 2026 | Burleson, TX
Customer requested a maintenance inspection before moving into their new home. We thoroughly inspected the system, including the wiring, safety switches, drains, filters, and indoor coil, and found everything to be clean and in good working condition. The system is operating properly and is ready for the new homeowners.
June 26, 2026 | Fort Worth, TX
Customer called because their A/C system was not cooling properly. We went out and inspected the unit and found that the transformer had tripped, causing the system to stop operating. We reset the transformer, checked the system operation, and confirmed everything is running properly and cooling as it should.
June 23, 2026 | Burleson, TX
We installed a new line set to the downstairs air handler and recharged the system with refrigerant. After completing the installation, we tested the system and confirmed everything is running properly and cooling as it should.
June 22, 2026 | Arlington, TX
We went out to the property and replaced a failed TXV. After installation, we performed a pressure test to ensure system integrity, then pulled a deep vacuum down to 500 microns. Once the system held properly, we recharged and adjusted the refrigerant levels, adding 5 lbs and 7 oz. The system is now ...