June 22, 2026 | Weatherford, TX
Customer scheduled a maintenance service for their A/C system. We performed a full inspection, washed the outdoor condenser coil, secured the unit door back in place, and checked the system operation. The amp draw was within proper range, and everything is clean and running properly.
June 18, 2026 | Arlington, TX
Customer called because their thermostat was displaying an error code. Upon inspection, we found the thermostat batteries were weak and replaced them. We also checked the refrigerant levels, changed the filter, and inspected the system's operation. Everything is working properly at this time, and the system is cooling as expected.
June 18, 2026 | Burleson, TX
We performed a thorough cleaning of both the evaporator coils and the outdoor condenser coils to improve system performance and efficiency. After cleaning, we checked the system and confirmed everything is clean, operating properly, and cooling as it should.
June 17, 2026 | Burleson, TX
Customer called because their mini-split system was not cooling properly. Upon inspection, we found a failed capacitor that was preventing the system from operating correctly. We replaced the capacitor, checked the compressor amp draw, and cleaned the outdoor condenser coil. The system is now cooling properly and running as it ...
June 17, 2026 | Aledo, TX
Customer called to schedule an A/C maintenance service. We inspected the system and found all wiring to be in good condition, refrigerant levels within specifications, and the air filter clean. The capacitor tested within the proper range. We also cleaned the outdoor condenser coil to help maintain efficiency. The ...
June 16, 2026 | Watuaga, TX
Customer requested a maintenance service and filter replacement. During our inspection, we found water dripping from several supply vents due to insufficient insulation. We insulated the affected ductwork, installed diffusers at the supply vents, and added additional supply vents in the dining area and kitchen to improve airflow. After completing ...
June 16, 2026 | Venus, TX
Customer requested an A/C maintenance service. We performed a complete inspection of the system and verified that all components are operating properly. The relay is functioning correctly, the coil is clean, and the compressor is running as it should. The system is in good condition and working well at ...
June 15, 2026 | Willow Park, TX
We installed a new 2-ton heat pump system, all new ductwork, and a non-programmable thermostat. The entire system was tested to ensure everything is operating properly and efficiently, providing reliable comfort for the home.
June 15, 2026 | Joshua, TX
Customer called because there was no airflow to the living room area. Upon inspection, we found that the mechanical damper was in the closed position. We adjusted the damper, restored proper airflow, and confirmed that the living room is now receiving adequate air.
June 15, 2026 | Alvarado, TX
Customer called stating the system was not cooling. Upon arrival, we found a broken wire at the high voltage plug and a failed run capacitor. We repaired the wiring issue, replaced the capacitor, and checked amp draws on the compressor and fan motor. Refrigerant levels were also verified and found ...
June 12, 2026 | Fort Worth, TX
Customer called to schedule a service visit because their system was not cooling properly. Upon inspection, we found that the fan wire was connected to the incorrect terminal on the run capacitor. We corrected the wiring, tested the system, and confirmed that everything is operating properly and cooling as it ...
June 12, 2026 | Joshua, TX
Customer called because water was pooling from the secondary drain line onto the back porch. Upon inspection, we found that the drain line was clogged and cleared the blockage. We tested the system, confirmed proper drainage, and verified that the unit is cooling properly with no further water pooling.
June 9, 2026 | Burleson, TX
Customer called and reported that their mini-split system was not cooling properly. Our technician inspected the unit and found that it was completely out of refrigerant, indicating a leak in the system. We recommended inspecting the flare fittings for cracks or damage to locate the source of the leak.