July 16, 2026 | Fort Worth, TX
Customer's drain pan had cracked and needed to be replaced. We installed a new drain pan, cleaned both the indoor evaporator coil and the outdoor condenser coil, and tested the system. Everything is now operating properly and draining as it should.
July 14, 2026 | Midlothian, TX
We contacted the customer to perform their routine maintenance as part of their maintenance agreement. Both the upstairs and downstairs systems were operating properly. We found high startup amp draw on the outdoor compressors, so we installed two soft start kits to reduce startup amps and replaced a capacitor as ...
July 14, 2026 | Fort Worth, TX
We were called out to the business because the system was not draining properly. We found the drain line was missing a P-trap, so we installed one to ensure proper drainage. The system is now operating and draining as it should.
July 11, 2026 | Fort Worth, TX
The customer called because the thermostat showed the temperature was rising. We found the condensate drain line was clogged, causing the safety switch to shut the system off. We cleared the drain line and P-trap, and the system is now running and cooling properly.
July 10, 2026 | Grand Prairie, TX
As part of our maintenance agreement program, we contacted the customer to schedule their routine maintenance. During the inspection, we found the system was low on refrigerant. We added the necessary refrigerant, and the system is now operating and cooling properly. All other components were working as expected.
July 10, 2026 | Alvarado, TX
The customer contacted us for a quote on a new mini-split system because their current unit was no longer cooling properly. We found the outdoor unit had a failed control board and compressor. The customer chose to move forward with the replacement, and we installed the new mini-split system along ...
July 10, 2026 | Fort Worth, TX
The customer called because their system was making a noise. We found the outdoor unit had a weak capacitor and replaced it. We also found the compressor has a high amp draw and would benefit from a start assist to help prevent future system failure. After replacing the capacitor, the ...
July 9, 2026 | Fort Worth, TX
Customer scheduled a two-system A/C maintenance. During the inspection, we found a loose blower motor shaft, a weak capacitor, and the compressor over-amping on startup. We replaced the blower motor and capacitor, installed two soft start kits, and tested both systems. Everything is now operating properly.
July 8, 2026 | Burleson, TX
Customer called because their home was not cooling properly. We found that the compressor was not starting due to a failed capacitor. We replaced the capacitor, tested the system, and confirmed everything is now running properly and cooling as it should.
July 8, 2026 | Forest Hill, TX
Customer requested a routine A/C maintenance. We performed a complete system inspection, checked all operating levels and amp draw, and verified that all components are functioning properly. The system is running efficiently and cooling as it should.
Total: 565